1932

Abstract

As minimally invasive surgical techniques progress, the demand for efficient, reliable methods for vascular ligation and tissue closure becomes pronounced. The surgical advantages of energy-based vessel sealing exceed those of traditional, compression-based ligatures in procedures sensitive to duration, foreign bodies, and recovery time alike. Although the use of energy-based devices to seal or transect vasculature and connective tissue bundles is widespread, the breadth of heating strategies and energy dosimetry used across devices underscores an uncertainty as to the molecular nature of the sealing mechanism and induced tissue effect. Furthermore, energy-based techniques exhibit promise for the closure and functional repair of soft and connective tissues in the nervous, enteral, and dermal tissue domains. A constitutive theory of molecular bonding forces that arise in response to supraphysiological temperatures is required in order to optimize and progress the use of energy-based tissue fusion. While rapid tissue bonding has been suggested to arise from dehydration, dipole interactions, molecular cross-links, or the coagulation of cellular proteins, long-term functional tissue repair across fusion boundaries requires that the reaction to thermal damage be tailored to catalyze the onset of biological healing and remodeling. In this review, we compile and contrast findings from published thermal fusion research in an effort to encourage a molecular approach to characterization of the prevalent and promising energy-based tissue bond.

Loading

Article metrics loading...

/content/journals/10.1146/annurev-bioeng-071516-044702
2018-06-04
2024-04-24
Loading full text...

Full text loading...

/deliver/fulltext/20/1/annurev-bioeng-071516-044702.html?itemId=/content/journals/10.1146/annurev-bioeng-071516-044702&mimeType=html&fmt=ahah

Literature Cited

  1. 1.  Phillips CK, Hruby GW, Durak E, Lehman DS, Humphrey PA et al. 2008. Tissue response to surgical energy devices. Urology 71:744–48
    [Google Scholar]
  2. 2.  Carbonell AM, Joels CS, Kercher KW, Matthews BD, Sing RF, Heniford BT 2003. A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small-, medium-, and large-sized arteries. J. Laparoendosc. Adv. Surg. Tech. A 13:377–80
    [Google Scholar]
  3. 3.  Pabittei DR, Heger M, van Tuijl S, Simonet M, de Boon W et al. 2015. Ex vivo proof-of-concept of end-to-end scaffold-enhanced laser-assisted vascular anastomosis of porcine arteries. J. Vasc. Surg. 62:200–9
    [Google Scholar]
  4. 4.  Alimova A, Chakraverty R, Muthukattil R, Elder S, Katz A et al. 2009. In vivo molecular evaluation of guinea pig skin incisions healing after surgical suture and laser tissue welding using Raman spectroscopy. J. Photochem. Photobiol. B 96:178–83
    [Google Scholar]
  5. 5.  Hu L, Lu Z, Wang B, Cao J, Ma X et al. 2011. Closure of skin incisions by laser-welding with a combination of two near-infrared diode lasers: preliminary study for determination of optimal parameters. J. Biomed. Opt. 16:038001
    [Google Scholar]
  6. 6.  Gayen TK, Katz A, Savage HE, McCormick SA, Al-Rubaiee M et al. 2003. Aorta and skin tissues welded by near-infrared Cr4+:YAG laser. J. Clin. Laser Med. Surg. 21:259–69
    [Google Scholar]
  7. 7.  Smulders JF, de Hingh IHJT, Stavast J, Jackimowicz JJ 2007. Exploring new technologies to facilitate laparoscopic surgery: creating intestinal anastomoses without sutures or staples, using a radio-frequency-energy-driven bipolar fusion device. Surg. Endosc. 21:2105–9
    [Google Scholar]
  8. 8.  Zhao L, Zhuo C, Song C, Li X, Zhou Y, Shi D 2015. Histological characteristics of collagen denaturation and injuries in bipolar radiofrequency-induced colonic anastomoses. Pathol. Res. Pract. 211:214–18
    [Google Scholar]
  9. 9.  Burt JD, Siddins M, Morrison W 2001. Laser photoirradiation in digital flexor tendon repair. Plast. Reconstr. Surg. 108:688–94
    [Google Scholar]
  10. 10.  Kilkelly FX, Choma TJ, Popovic N, Miller DW, Sweet DE 1996. Tendon repair by laser welding: a histologic and biomechanical comparison and suture repair with CO2 and argon lasers. Lasers Surg. Med. 19:487–91
    [Google Scholar]
  11. 11.  Lauto A, Dawes JM, Piper JA, Owen ER 1998. Laser nerve repair by solid protein band technique. II. Assessment of long-term nerve regeneration. Microsurgery 18:60–64
    [Google Scholar]
  12. 12.  Stylianopoulos T, Aksan A, Barocas VH 2008. A structural, kinetic model of soft tissue thermomechanics. Biophys. J. 94:717–25
    [Google Scholar]
  13. 13.  Wright NT, Humphrey JD 2002. Denaturation of collagen via heating: an irreversible rate process. Annu. Rev. Biomed. Eng. 4:109–28
    [Google Scholar]
  14. 14.  Tang J, Godlewski G, Rouy S, Delacrétaz G 1997. Morphologic changes in collagen fibers after 830 nm diode laser welding. Lasers Surg. Med. 21:438–43
    [Google Scholar]
  15. 15.  Figueiredo RLP, Dantas MSS, Oréfice RL 2011. Thermal welding of biological tissues derived from porcine aorta for manufacturing bioprosthetic cardiac valves. Biotechnol. Lett. 33:1699–703
    [Google Scholar]
  16. 16.  Murray LW, Su L, Kopchok GE, White RA 1989. Crosslinking of extracellular matrix proteins: a preliminary report on a possible mechanism of argon laser welding. Lasers Surg. Med. 9:490–96
    [Google Scholar]
  17. 17.  Schober R, Ulrich F, Sander T, Dürselen H, Hessel S 1986. Laser-induced alteration of collagen substructure allows microsurgical tissue welding. Science 232:1421–22
    [Google Scholar]
  18. 18.  Fenner JW, Martin W, Moseley H, Wheatley DJ 1994. Dehydration: a model for (low-temperature) argon laser tissue bonding. Phys. Med. Biol. 39:2147–60
    [Google Scholar]
  19. 19.  White RA, Kopchok G, Peng S-K, Fujitani R, White G et al. 1987. Laser vascular welding—how does it work?. Ann. Vasc. Surg. 1:461–64
    [Google Scholar]
  20. 20.  Winter H, Holmer C, Buhr HJ, Lindner G, Lauster R et al. 2010. Pilot study of bipolar radiofrequency-induced anastomotic thermofusion—exploration of therapy parameters ex vivo. Int. J. Colorectal Dis. 25:129–33
    [Google Scholar]
  21. 21.  Wolf–de Jonge ICDYM, Beek JF, Balm R 2004. 25 years of laser assisted vascular anastomosis (LAVA): What have we learned?. Eur. J. Vasc. Endovasc. Surg. 27:466–76
    [Google Scholar]
  22. 22.  Brennan MJ, Kilbride BF, Wilker JJ, Liu JC 2017. A bioinspired elastin-based protein for a cytocompatible underwater adhesive. Biomaterials 124:116–25
    [Google Scholar]
  23. 23.  Feldman L, Fuchshuber P, Jones DB 2012. The SAGES Manual on the Fundamental Use of Surgical Energy (FUSE) New York: Springer
    [Google Scholar]
  24. 24.  Vladimirova IA, Lankin YN, Philyppov IB, Sushiy LF, Shuba YM 2014. Frequency dependence of excitation-contraction of multicellular smooth muscle preparations: the relevance to bipolar electrosurgery. J. Surg. Res. 186:119–25
    [Google Scholar]
  25. 25.  Smith R, Pasic R 2008. The role of vessel sealing technologies in laparoscopic surgery. Surg. Technol. Int. 17:208–12
    [Google Scholar]
  26. 26.  Katchinskiy N, Godbout R, Goez HR, Elezzabi AY 2014. Femtosecond laser-induced cell-cell surgical attachment: femtosecond laser cell–cell attachment. Lasers Surg. Med. 46:335–41
    [Google Scholar]
  27. 27.  Sriramoju V, Savage HE, Katz A, Chakraverty R, Budansky Y et al. 2008. NIR-laser tissue welding in an in vivo guinea pig animal model. Proc. SPIE 6854:685405
    [Google Scholar]
  28. 28.  Barton MJ, Morley JW, Stoodley MA, Lauto A, Mahns DA 2014. Nerve repair: toward a sutureless approach. Neurosurg. Rev. 37:585–95
    [Google Scholar]
  29. 29.  Elvin CM, Brownlee AG, Huson MG, Tebb TA, Kim M et al. 2009. The development of photochemically crosslinked native fibrinogen as a rapidly formed and mechanically strong surgical tissue sealant. Biomaterials 30:2059–65
    [Google Scholar]
  30. 30.  Lauto A, Poppas DP, Murrell GAC 1998. Solubility study of albumin solders for laser tissue-welding. Lasers Surg. Med. 23:258–62
    [Google Scholar]
  31. 31.  Lauto A, Trickett R, Malik R, Dawes J, Owen E 1997. Laser-activated solid protein bands for peripheral nerve repair. Lasers Surg. Med. 21:134–41
    [Google Scholar]
  32. 32.  Harold KL, Pollinger H, Matthews BD, Kercher KW, Sing RF, Heniford BT 2003. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg. Endosc. 17:1228–30
    [Google Scholar]
  33. 33.  Kennedy JS, Stranahan PL, Taylor KD, Chandler JG 1998. High burst-strength, feedback-controlled bipolar vessel sealing. Surg. Endosc. 12:876–78
    [Google Scholar]
  34. 34.  Targarona EM, Balague C, Marin J, Neto RB, Martinez C et al. 2005. Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis. Surg. Innov. 12:339–44
    [Google Scholar]
  35. 35.  Campbell PA, Cresswell AB, Frank TG, Cuschieri A 2003. Real-time thermography during energized vessel sealing and dissection. Surg. Endosc. 17:1640–45
    [Google Scholar]
  36. 36.  Floume T, Syms RRA, Darzi AW, Hanna GB 2010. Optical, thermal, and electrical monitoring of radio-frequency tissue modification. J. Biomed. Opt. 15:018003
    [Google Scholar]
  37. 37.  Lim C, Goldin R, Elson D, Darzi A, Hanna G 2010. In vivo thermography during small bowel fusion using radiofrequency energy. Surg. Endosc. 24:2465–74
    [Google Scholar]
  38. 38.  Su L, Fonseca MB, Arya S, Kudo H, Goldin R et al. 2014. Laser-induced tissue fluorescence in radiofrequency tissue-fusion characterization. J. Biomed. Opt. 19:015007
    [Google Scholar]
  39. 39.  Lamberton GR, Hsi RS, Jin DH, Lindler TU, Jellison FC, Baldwin DD 2008. Prospective comparison of four laparoscopic vessel ligation devices. J. Endourol. 22:2307–12
    [Google Scholar]
  40. 40.  Hruby GW, Marruffo FC, Durak E, Collins SM, Pierorazio P et al. 2007. Evaluation of surgical energy devices for vessel sealing and peripheral energy spread in a porcine model. J. Urol. 178:2689–93
    [Google Scholar]
  41. 41.  Newcomb WL, Hope WW, Schmelzer TM, Heath JJ, Norton HJ et al. 2009. Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices. Surg. Endosc. 23:90–96
    [Google Scholar]
  42. 42.  Richter S, Kollmar O, Neunhoeffer E, Schilling MK, Menger MD, Pistorius G 2006. Differential response of arteries and veins to bipolar vessel sealing: evaluation of a novel reusable device. J. Laparoendosc. Adv. Surg. Tech. A 16:149–55
    [Google Scholar]
  43. 43.  Krause D 2016. JustRight surgical vessel sealing system. https://www.accessdata.fda.gov/cdrh_docs/pdf16/K160602.pdf
  44. 44.  Fankell DP, Kramer E, Cezo J, Taylor KD, Ferguson VL, Rentschler ME 2016. A novel parameter for predicting arterial fusion and cutting in finite element models. Ann. Biomed. Eng. 44:3295–306
    [Google Scholar]
  45. 45.  Cezo JD, Kramer EA, Schoen JA, Ferguson VL, Taylor KD, Rentschler ME 2015. Tissue storage ex vivo significantly increases vascular fusion bursting pressure. Surg. Endosc. 29:1999–2005
    [Google Scholar]
  46. 46. Valleylab. 2004. 510(k) notification. Summary of safety and effectiveness information: LigaSure™ vessel sealing system. https://www.accessdata.fda.gov/cdrh_docs/pdf4/K043273.pdf
  47. 47.  Cezo JD, Passernig AC, Ferguson VL, Taylor KD, Rentschler ME 2014. Evaluating temperature and duration in arterial tissue fusion to maximize bond strength. J. Mech. Behav. Biomed. Mater. 30:41–49
    [Google Scholar]
  48. 48.  Person B, Vivas DA, Ruiz D, Talcott M, Coad JE, Wexner SD 2008. Comparison of four energy-based vascular sealing and cutting instruments: a porcine model. Surg. Endosc. 22:534–38
    [Google Scholar]
  49. 49.  Sindram D, Martin K, Meadows JP, Prabhu AS, Heath JJ et al. 2011. Collagen–elastin ratio predicts burst pressure of arterial seals created using a bipolar vessel sealing device in a porcine model. Surg. Endosc. 25:2604–12
    [Google Scholar]
  50. 50.  Anderson N, Kramer E, Cezo J, Ferguson V, Rentschler ME 2014. Tissue bond strength as a function of applied fusion pressure. J. Med. Devices 8:030925
    [Google Scholar]
  51. 51.  Landman J, Kerbl K, Rehman J, Andreoni C, Humphrey PA et al. 2003. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J. Urol. 169:697–700
    [Google Scholar]
  52. 52.  Serure A, Withers EH, Thomsen S, Morris J 1984. Comparison of carbon dioxide laser–assisted microvascular anastomosis and conventional microvascular sutured anastomosis. Surg. Forum 34:634–36
    [Google Scholar]
  53. 53.  Arya S, Hadjievangelou N, Lei S, Kudo H, Goldin RD et al. 2013. Radiofrequency-induced small bowel thermofusion: an ex vivo study of intestinal seal adequacy using mechanical and imaging modalities. Surg. Endosc. 27:3485–96
    [Google Scholar]
  54. 54.  Shields CA, Schechter DA, Tetzlaff P, Baily AL, Dycus S, Cosgriff N 2004. Method for creating ideal tissue fusion in soft-tissue structures using radio frequency (RF) energy. Surg. Technol. Int. 13:49–55
    [Google Scholar]
  55. 55.  Ngeow WC 2010. Scar less: a review of methods of scar reduction at sites of peripheral nerve repair. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endodontol. 109:357–66
    [Google Scholar]
  56. 56.  Matteini P, Rossi F, Menabuoni L, Pini R 2007. Microscopic characterization of collagen modifications induced by low-temperature diode-laser welding of corneal tissue. Lasers Surg. Med. 39:597–604
    [Google Scholar]
  57. 57.  Small W IV, Celliers PM, Kopchok GE, Reiser KM, Heredia NJ et al. 1997. In-vivo argon laser vascular welding using thermal feedback: open- and closed-loop patency and collagen crosslinking. Proc. SPIE 2970:252–56
    [Google Scholar]
  58. 58.  Züger BJ, Ott B, Mainil-Varlet P, Schaffner T, Clémence J-F et al. 2001. Laser solder welding of articular cartilage: tensile strength and chondrocyte viability. Lasers Surg. Med. 28:427–34
    [Google Scholar]
  59. 59.  Mecham RP 2011. The Extracellular Matrix: An Overview Berlin: Springer
  60. 60.  Ramachandran GN, Kartha G 1954. Structure of collagen. Nature 174:269–70
    [Google Scholar]
  61. 61.  Kramer RZ, Bella J, Mayville P, Brodsky B, Berman HM 1999. Sequence dependent conformational variations of collagen triple-helical structure. Nature 6:454–57
    [Google Scholar]
  62. 62.  Sriramoju V, Alfano RR 2015. In vivo studies of ultrafast near-infrared laser tissue bonding and wound healing. J. Biomed. Opt. 20:108001
    [Google Scholar]
  63. 63.  Hynes RO, Yamada KM 2012. Extracellular Matrix Biology Cold Spring Harbor, NY: Cold Spring Harbor Lab. Press
  64. 64.  Robins SP 2007. Biochemistry and functional significance of collagen cross-linking. Biochem. Soc. Trans. 35:849–52
    [Google Scholar]
  65. 65.  Tang J, O'Callaghan D, Rouy S, Godlewski G 1998. Quantitative changes in collagen levels following 830-nm diode laser welding. Lasers Surg. Med. 22:207–11
    [Google Scholar]
  66. 66.  Miles CA, Burjanadze TV, Bailey AJ 1995. The kinetics of the thermal denaturation of collagen in unrestrained rat tail tendon determined by differential scanning calorimetry. J. Mol. Biol. 245:437–46
    [Google Scholar]
  67. 67.  Guthrie CR, Murray LW, Kopchok GE, Rosenbaum D, White RA 1991. Biochemical mechanisms of laser vascular tissue fusion. J. Investig. Surg. 4:3–12
    [Google Scholar]
  68. 68.  Pearce JA, Thomsen S 1993. Kinetic models of laser-tissue fusion processes. Biomed. Sci. Instrum. 29:355–60
    [Google Scholar]
  69. 69.  Chen RK, Chastagner MW, Geiger JD, Shih AJ 2014. Bipolar electrosurgical vessel-sealing device with compressive force monitoring. J. Biomech. Eng. 136:061001
    [Google Scholar]
  70. 70.  Larson M, Sooklal V, McClure J, Hooper L, Sieber J 2011. A laser device for fusion of nasal mucosa. Head Neck Oncol 2:Suppl. 1O23
    [Google Scholar]
  71. 71.  Santini M, Vicidomini G, Baldi A, Gallo G, Laperuta P et al. 2006. Use of an electrothermal bipolar tissue sealing system in lung surgery. Eur. J. Cardio-Thorac. Surg. 29:226–30
    [Google Scholar]
  72. 72.  Bass LS, Treat MR 1995. Laser tissue welding: a comprehensive review of current and future clinical applications. Lasers Surg. Med. 17:315–49
    [Google Scholar]
  73. 73.  Cezo JD, Kramer EA, Taylor KD, Ferguson VL, Rentschler ME 2013. Tissue fusion bursting pressure and the role of tissue water content. Proc. SPIE 8584:85840M
    [Google Scholar]
  74. 74.  Xu D, Tsai C-J, Nussinov R 1997. Hydrogen bonds and salt bridges across protein–protein interfaces. Protein Eng 10:999–1012
    [Google Scholar]
  75. 75.  Miles CA, Avery NC, Rodin VV, Bailey AJ 2005. The increase in denaturation temperature following cross-linking of collagen is caused by dehydration of the fibres. J. Mol. Biol. 346:551–56
    [Google Scholar]
  76. 76.  Murata K, Nakazawa K, Hamai A 1975. Distribution of acidic glycosaminoglycans in the intima, media and adventitia of bovine aorta and their anticoagulant properties. Atherosclerosis 21:93–103
    [Google Scholar]
  77. 77.  Kramer EA, Cezo JD, Fankell DP, Taylor KD, Rentschler ME, Ferguson VL 2016. Strength and persistence of energy-based vessel seals rely on tissue water and glycosaminoglycan content. Ann. Biomed. Eng. 44:3421–31
    [Google Scholar]
  78. 78.  Lorenzo AC, Caffarena ER 2005. Elastic properties, Young's modulus determination and structural stability of the tropocollagen molecule: a computational study by steered molecular dynamics. J. Biomech. 38:1527–33
    [Google Scholar]
  79. 79.  Aksan A, Hubel A, Bischof JC 2009. Frontiers in biotransport: water transport and hydration. J. Biomech. Eng. 131:074004
    [Google Scholar]
  80. 80.  Gineyts E, Borel O, Chapurlat R, Garnero P 2010. Quantification of immature and mature collagen crosslinks by liquid chromatography–electrospray ionization mass spectrometry in connective tissues. J. Chromatogr. B 878:1449–54
    [Google Scholar]
/content/journals/10.1146/annurev-bioeng-071516-044702
Loading
  • Article Type: Review Article
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error